Electrical Panel Wiring Layout - I see you propose to go 12 awg cord for nearly the whole thing (that's what 20a breakers imply) - it is outstanding. Feel free to kick the refrigerator and smoke detector up to 12awg additionally - that manner you do not have to shop for any 14awg twine. I don't personal any! If you have some other motive to apply a 15a breaker you're welcome to apply that on a circuit stressed in 12awg.

I am doing a major kitchen and toilet redesign assignment and determined the antique federal pacific breaker box wishes to be replaced. On account that i will be rewiring the bath and kitchen, i figured it makes experience to plan to subsequently rewire the entire house.

Yes, you want a four wire connection (2 legs hot, neutral, and floor) from the main to the sub panel. Additionally the sub desires to be grounded, as you have got deliberate ground rods you're ready there.

I made a spreadsheet with all of the modern-day and destiny masses i may additionally add to the house then sectioned them off into extraordinary department circuits with the type of breaker so one can protect them. Might someone mind taking a examine my deliberate-out wiring and permit me realize if it looks accurate or if i am missing some thing apparent? I hope to get a few feedback about first-rate practices for planning residence circuits and what strategies are had to guard them, using nec 2014 for reference (i live in portland, or).

There may be nothing wrong with greater ground rods. Go nuts. The key's that every one the grounds are connected to every different by cord - and they may be not connected to neutral everywhere besides one vicinity - the principle carrier panel.

I might go together with a far larger panel. You have got both -1 or three circuits left, and that's too little headroom for my comfort. Getting a bigger panel is dirt cheap compared to the value of changing flawlessly properly breakers with duplex breakers (i name them double-stuff) merely to shoehorn everything in. Also, larger panels in mixture-packs include more breakers and this is far-and-away the cheapest way to shop for breakers. Any other cause to keep away from duplex breakers is if you ever need afci, gfci or some thing destiny component comes out - the ones are lots greater costly in duplex breakers due to the miniaturization required. Don't think you need to use a 100a panel - you can use a larger panel (200a), you simply can not use a smaller one (70a).