honeywell two stage thermostat wiring diagram 2 Stage Thermostat Wiring Diagram Image Honeywell, Furnace To Heil 1024×904 14 New Honeywell, Stage Thermostat Wiring Diagram Galleries

14 New Honeywell, Stage Thermostat Wiring Diagram Galleries

Related photos in this diagram:

Other recommended diagram ideas:

2 Stage Thermostat Wiring Diagram Image Honeywell, Furnace To Heil 1024×904 - With so many new functions on these days’s thermostats (t-stats), there are many more wires to attach up whilst putting in a brand new or substitute t-stat. Gone are the 2-wire days.? in the ones instances, all you needed became one cord from the furnace transformer.? plus, you had another to feed energy to a fuel valve or relay to turn the warmth on and off. But as cited, nowadays’s t-stats, with their ever developing characteristic listing, have more wires to ring out.? so here, we show examples of honeywell thermostat wiring diagram four wire for those better twine be counted t-stats.? here, we focus at the four cord t-stats.

Cord colour, typicalletter designationpurpose apower gift right here while any heating or cooling is operating inside the hvac gadget. Aux/e, w2operates 2d heating level, or when controlling a warmness pump, the emergency warmth stage. Bluebactivates the changeover to heat relay / valves in hvac structures. Brown, blue, pink, black. C24 volts ac. The commonplace lead of the transformer. All furnace switched components have one facet in their power related to this lead. Browneactivates emergency warmness relay greengoperates the inner fan kmay spark off emergency warmth relay in some installations. Also used between a thermostat and honeywell twine savers. Lheat pump display light. Can also turn on while emergency heat is operating. Orangeoactivates the changeover to chill relay / valves in hvac systems. O/b, w, w1operates first heating level. For heat pumps, turns on the compressor in warmth mode. Pdefrost operation in development lamp; comes on while either the hvac compressor outside has switched into defrost mode. Redr24 volts ac ???? Redrc24 volts ac supply to cooling relay in hvac gadget. Redrh24 volts ac deliver to heating relay in hvac system. Whitew1, w, o/boperates first heating level. For warmth pumps, turns on the compressor in heat mode. W2 - aux/eoperates 2nd heating stage, or while controlling a warmth pump, the emergency heat degree. Xmalfunction alert lamp. Voltage gift whilst the hvac gadget detects a trouble in its additives. Yellowy1, yoperates first stage compressor cooling. Y2operates 2d cooling stage. Y, y1operates first stage compressor cooling. S1, s2outdoor temperature sensor (s) wires.