Advertisement
thermostat zone valve wiring diagram Honeywell Zone Valve Wiring Diagram, fonar.me 13 Nice Thermostat Zone Valve Wiring Diagram Ideas

13 Nice Thermostat Zone Valve Wiring Diagram Ideas

Related photos in this diagram:

Other recommended diagram ideas:

Nice Thermostat Zone Valve Wiring Diagram Ideas - A few years returned i transformed about 1/four-1/3 or my house into hydronic radiant ground warmness strolling off identical area as the baseboard. The fellow who sweated the tubes and zoned it out has never come back to hook up the area controller.

After i got into that trouble years ago i used to be wiring up a honeywell area valve to a device already using aptitude zone valves. I referred to as my heating dealer who had dave ferris (now retired) on deck to answer wiring questions.

Region-a-trol valves need to not be stressed out in the equal circuit with zone valves of a special make or manufacturer without first consulting your local quarter-a-trol consultant or our manufacturing unit engineering department for unique wiring statistics. [2].

Well wired, the individual thermostat calls for heat, the sector valve opens, whilst the valve is fully open an give up transfer within the valve connects a 2d pair of wires that switch on the circulator pump lower back on the boiler.

Will i think this will assist clear matters up a bit for wiring a third heating region the usage of a area valve method: while the tt calls for warmth (yes 2 cord is best) it tells the sector valve for its area to open. While the quarter valve is fully open it in flip tells the circulator pump to begin pumping. (There is an "quit transfer" in the region valve that performs this 2nd feature). So that you'll find a pair of wires from tt to the quarter valve and 2 wires from the quarter valve to the circulator relay. Be careful even though: the wiring connections can range a piece among zone valve brands - if all of yours are the identical emblem you could take a look at the prevailing valve, comply with the wires, and you'll see how the zone valve is installed. If there are exclusive manufacturers you may want to invite for a clue from your hvac dealer or the producer.

If so, is there anything i need to be aware of, like probably wiring it backwards and frying something ? If i will just add the brand new "loop" without delay to the aquastat, in what order are the connections made ? Example, aquastat to at least one connection at valve, 2d connection at valve to at least one connection at thermostat, different connection at thermostat again to aquastat ?.